Skip Navigation LinksPressure Washers > Stationary > Series 3000, 5000, 6000

Stationary Pressure Washers

Series 3000, 5000, 6000

Standard Features
  • ETL Listed
  • Heavy Duty Tubular Steel Frame
  • Heavy Duty Legs
  • Durable Hi-gloss Powder Coated Paint
  • Stainless Steel Compartment Covers
  • Stainless Steel Combustion Chamber
  • Heating Coil Constructed of ASTM A53 Schedule 80 Steel Pipe
  • Fuel Efficient Combustion Chamber
  • Adjustable Temperature Control
  • High-limit Temperature Control
  • Waterproof Ignition Transformer
  • Pressure Relief Valve
  • Belt Driven Pump
  • Trigger Gun Control
  • Stainless Steel Float Tank
  • Low Water Shut-off Protection
  • Wire Braid Discharge Hose
  • Quick Coupled Stainless Steel Nozzles
  • Automatic Shutdown Timer
  • Watertight Electrical Panel
  • Diagnostic Control Monitoring Lights
  • Calibrated Detergent Mixing Valve
  • Fuel Water Separator
  • Electronic Ignition
  • Hour Meter
  • Soap Solenoid
  • Cad Cell Flame Sensor (Oil fired units)
  • Draft Diverter
Control Panel
Easy to understand accessible controls make the AaLadin Pressure Washer simple and safe to operate. The calibrated detergent mixing valve precisely meters detergent allowing for high-pressure soap application.
Dual Pump Module
AaLadin's standard features are designed to promote longer life. Quality features such as the belt driving the pump enhance trouble free operation by isolating heat and vibration from the pump and allowing for overload protection. The 6000 series pump module shown utilizes a dual pump configuration to minimize the possibility of down time from the possibility of pump failure.
Draft Diverter
Protect your hot water machine from the updrafts that can extinguish the pilot light on gas machines and hinder proper venting of the exhaust with this draft diverter. It fits easily on top of the stack head and is standard equipment on all gas fired machines.
Pump Module Access
Front panel opens and raises up out of the way for easy access to the pump and motor area.
Remote Control Station
The remote operation station allows the user the ability to operate the panel controls away from the unit. All remote control stations are 24 volts.
Easy Burner Accessibility
End panel door opens allowing spacious easy access to burner and gas valve.
Heat Chamber - AaLadin Exclusive
The AaLadin heating chamber construction provides long life and fuel efficiencies unsurpassed in the industry. Coils are made of high test ASTM A53 steel pipe wound on a spiral helix with special hot gas baffling. We blanket insulate the entire chamber with a highly efficient insulation blanket with low heat storage and high heat reflectance.Our burner system has a worldwide reputation for superior performance and reliability.
ETL Listed
All models in standard configuration are ETL Listed to ensure safety and the capability of meeting electrical code requirements. (Steam Combination units not ETL Listed)
3000
With 1600 to 3000 PSI high pressure, 300 PSI steam, and 3.0 to 5.0 GPM these stationary pressure washers have exceptional power to get the job done fast.
Model 3303 3416 3423 3430 3518 3523 3530
Flow Output (GPM) 3 4 4 4 5 5 5
Pressure Ratings (PSI) 300 1600 2300 3000 1800 2300 3000
Max Output Temperature (°F) 300° 210° 210° 210° 210° 210° 210°
Cleaning Comparison Index (1) 5812 15112 18118 20693 20036 22648 25866
Motor Horsepower .75 4 6 8/7.5 6 8/7.5 10
Electrical Requirements
Volt 115 230 230 230 230 230 230
Amp 10 20/15 20/15 30/25 30/20 30/25 30
Phase 1 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 3
Oil Fired Burner System
Input BTU's 420,000 350,000 350,000 350,000 420,000 420,000 420,000
Fuel Consumption (GPH) (2) 1.8 1.5 1.5 1.5 1.8 1.8 1.8
Burner Fuel Tank Capacity 15.5 15.5 15.5 15.5 15.5 15.5 15.5
Stack Size 8" 8" 8" 8" 8" 8" 8"
Gas Fired Burner System
Input BTU's 440,000 400,000 400,000 400,000 440,000 440,000 440,000
Fuel Consumption NG (CFH) (2) 264 240 240 240 264 264 264
Fuel Consumption LP (LBH) (2) 13.1 11.91 11.91 11.91 13.1 13.1 13.1
LP Tank Minimum Size 100# 100# 100# 100# 100# 100# 100#
Stack Size 10" 10" 10" 10" 10" 10" 10"
Discharge Hose 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50'
Approx. Weight (lbs) 730 728 776 794 824 848 848
Dimensions
Length 56" 56" 56" 56" 56" 56" 56"
Width 24" 24" 24" 24" 24" 24" 24"
Height 55" 55" 55" 55" 55" 55" 55"
5000
For extra cleaning power, this series makes short work of tough jobs with 1800 to 3000 PSI high pressure, 300 PSI steam and 4.0 to 6.0 GPM.
Model 5403 5518 5523 5530 5615 5622 5630
Flow Output (GPM) 4 5 5 5 6 6 6
Pressure Ratings (PSI) 300 1800 2300 3000 1500 2200 3000
Max Output Temperature (°F) 300° 210° 210° 210° 210° 210° 210°
Cleaning Comparison Index (1) 7750 20236 22648 25866 21948 26581 31039
Motor Horsepower 2 6 8/7.5 10 6 10 15
Electrical Requirements
Volt 115 230 230 230 230 230 230
Amp 15 30/20 30/25 30 30/20 30 35
Phase 1 1 or 3 1 or 3 3 1 or 3 3 3
Oil Fired Burner System
Input BTU's 726,000 487,000 487,000 487,000 585,000 585,000 585,000
Fuel Consumption (GPH) (2) 3.11 2.09 2.09 2.09 2.51 2.51 2.51
Burner Fuel Tank Capacity 25 25 25 25 25 25 25
Stack Size 10" 10" 10" 10" 10" 10" 10"
Gas Fired Burner System
Input BTU's 770,000 545,000 545,000 545,000 670,000 670,000 670,000
Fuel Consumption NG (CFH) (2) 462 327 327 327 402 402 402
Fuel Consumption LP (LBH) (2) 22.92 16.23 16.23 16.23 19.95 19.95 19.95
LP Tank Minimum Size 100# 100# 100# 100# 100# 100# 100#
Stack Size 12" 12" 12" 12" 12" 12" 12"
Discharge Hose 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50' 3/8" x 50'
Approx. Weight (lbs) 1030 1005 1060 1070 1060 1050 1000
Dimensions
Length 64" 64" 64" 64" 64" 64" 64"
Width 28" 28" 28" 28" 28" 28" 28"
Height 58" 58" 58" 58" 58" 58" 58"
6000
1200 to 2500 PSI high pressure, 500 PSI steam and 6.7 to 12.0 GPM. Engineered with the toughest jobs in mind, this series is top of the line in stationary pressure washers.
Model 6065 6112 6122 6218 6225
Flow Output (GPM) 6.7 10 10 12 12
Pressure Ratings (PSI) 500 1200 2220 1800 2500
Max Output Temperature (°F) 300° 210° 210° 210° 210°
Cleaning Comparison Index (1) 16750 32719 44301 48086 56670
Motor Horsepower 4 7.5 15 15 20
Electrical Requirements
Volt 230 230 230 230 230
Amp 22 30 42 42 54
Phase 1 3 3 3 3
Oil Fired Burner System
Input BTU's 1,100,000 920,000 920,000 1,100,000 1,100,000
Fuel Consumption (GPH) (2) 4.71 3.94 3.94 4.71 4.71
Burner Fuel Tank Capacity 41 41 41 41 41
Stack Size 16" 16" 16" 16" 16"
Gas Fired Burner System
Input BTU's 1,200,000 1,000,000 1,000,000 1,200,000 1,200,000
Fuel Consumption NG (CFH) (2) 720 600 600 720 720
Fuel Consumption LP (LBH) (2) 35.73 29.77 29.77 35.73 35.73
LP Tank Minimum Size 100# 100# 100# 100# 100#
Stack Size 16" 16" 16" 16" 16"
Discharge Hose 1/2" x 50' 1/2" x 50' 1/2" x 50' 1/2" x 50' 1/2" x 50'
Approx. Weight (lbs) 2078 1940 2115 2415 2500
Dimensions
Length 84" 84" 84" 84" 84"
Width 36" 36" 36" 36" 36"
Height 84" 84" 84" 84" 84"


(1) Fuel Consumption considers an operating duty cycle of 60%.
(2) Cleaning Comparison Index - This is used in the comparison of pressure washing equipment by taking into account the cleaning effects of water pressure, flow and temperature on cleaning time. The larger the comparison index, the faster the pressure washer will clean. The formula is GPM x 60 x Square Root PSI x [1 + (TEMP -32°) / 310].